User Tools

Site Tools


en:altimet

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:altimet [2018/12/30 13:22] – [Communication with sensors] fluktuaciaen:altimet [Unknown date] (current) – external edit (Unknown date) 127.0.0.1
Line 30: Line 30:
 ===== Parameters ===== ===== Parameters =====
  
-When measuring the parameters of MPL3115A2 during the [[en:abl|ABL01A]] project, we found out that the pressure measurements were functional at least up to 16 km (approximately 10kPa), a much better than the parameter stated in the catalogue list. On the other hand, the internal pressure atmospheric model is only usable up to 10 km of altitude - in higher altitudes it experiences considerable inaccuracies. +When measuring the parameters of MPL3115A2 during the [[en:abl|ABL01A]] project, we found out that the pressure measurements were functional at least up to 16 km (approximately 10kPa), a much better result than the parameter stated in the catalogue list. On the other hand, the internal pressure atmospheric model is only usable up to 10 km of altitude - in higher altitudes it experiences considerable inaccuracies. 
  
  
Line 40: Line 40:
  
  
-Reading the pressure via I2C bus, a following python code was used: [[https://github.com/MLAB-project/MLAB-I2c-modules|Externí odkaz]] +Reading the pressure via I2C bus, a following python code was used: [[https://github.com/MLAB-project/MLAB-I2c-modules|External link]] 
  
 ==== Modul power supply ==== ==== Modul power supply ====
en/altimet.1546176140.txt.gz · Last modified: 2018/12/30 13:22 (external edit)